Intelligent control system first brand

Global 100 enterprises designated suppliers

Welcome to Shenzhen Chenjie Electron Co., Ltd. official website!

Service Hotline

+86-755-26518500

辰杰电子Chenjie Electron

Hot Keywords:  High power remote control, Wireless Controller, Wireless receiver module

Product Categories
GSM phone alarm CHJ-6250 SMS alarm
    Publish time 2017-05-20 16:18    
GSM phone alarm CHJ-6250 SMS alarm
Model: GSM phone phone card phone burglar alarm CHJ-6250 can send a short message or call to control all the dynamic home, specifically for the convenience of telephone line design, eliminating the need for telephone lines (such as car interior, remote Area, field, parking and other places that are not convenient to pick up the telephone line) as long as your phone card can be used normally, whether Unicom or China Mobile, can be used in the machine)
Commercial / home GSM alarm is widely used in home, residential property, electricity, transportation, oil, coal, railways, municipal, public security and other sectors of the security device, data monitoring and remote monitoring system. The original two remote control, a power supply, a siren, a host, a human body infrared detectors. A door, if you need to match with our security accessories area matching.

First, how to understand the basic functions of the host
1, the host using two frequency, quad-band GSM / GPRS industrial module, stable and reliable, the world can use.
2, support GSM / CDMA mobile phone, compatible with the Chinese / English short message alarm function, mobile alarm and arm and disarm defense.
3, can be set to 5 groups of user phone number.
4, can be set 1 group alarm center phone number room number information, can be security to the district, 110 network alarm management center alarm.
5, can be set to a group of deployment center phone number, the user will be deployed to the deployment center telephone dialing tips.
6, can be set to a group of disarming center phone number, the user disarmed when the withdrawal of the central telephone dialing tips.
7, the scene monitoring function: can clearly hear the scene of the voice, people move, dig, pry and other action sounds.
8, on-site intercom features: on-site staff propaganda, duplex intercom.
9, the host power off tips (within the spare battery): AC power, call SMS inform the user.
10, through the wireless remote control, can be deployed at home, out of the deployment, disarm or emergency alarm, convenient and practical.
11, through the remote into the phone for remote control on-site deployment, disarm, monitor, remote control output, host function settings.
12, can send text messages by remote control site deployment, disarm, monitor, remote control output, host function settings.
13, the owner can call or send text messages, remote control two output, control room lights, air conditioning switches and so on.
14, the host has a 3-way wired input control, open circuit, short circuit detection can be, easy to connect a variety of wired alarm equipment.
15, the host has 16 kinds of wireless anti-theft detectors (wireless on the radio fence, smoke, gas, emergency button, etc.)
16, the host has an alarm control relay output, easy to linkage power, video and so on.
17, the host has a password operation, to ensure system security.
18, external speaker interface, mute / siren alarm conversion.
19, the host of 3-way cable zone, 16-way wireless zone can be a separate cloth Sa defense, to facilitate the use of different regions.
20, the host can be equipped with built-in battery pack, AC-DC automatic conversion, automatic charging system to ensure that the power to work properly.
21, all wireless systems, no wiring, easy installation. Especially for garage, warehouse and other wired network can not reach the place.
 
Second, how to identify the host side of the pin function
 
 
1, SIM card.
2, the microphone: in the radius of 10-20 meters to send a clear voice.
3, 10-pin terminal: ① GND is the ground lead; ②SIREN is the external alarm number leads directly connected to the active alarm, the other end of the alarm ground; ③ ④ RELAY is the internal relay leads, usually feet off, Note: 1. OUT1, ⑦OUT2 is the control output, remote control output through the remote, external interface circuit can control the room lights, Air conditioning switch, etc .; ⑧IN3, ⑨IN2, ⑩IN1 is a wired input, each port to the ground short circuit or ground can trigger the alarm.
 
Third, how to open the host power to understand the host working state
1, receive module antenna seat NATA, frequency 433MHZ.
2, the function reset button (RESET), press and hold the reset button (RESET) and then plug in the power, the system returns to the initial state, the password is 123456, the host memory of all detectors empty.
3, two-color LED lights, in different strokes on behalf of different working conditions.
4, power switch, ON is on, OFF is off.
5, the power outlet, the core is 12V positive power supply.
6, NATB communication module antenna seat, the frequency of 900-1800MHZ.
The basic steps: the pressure of the tip of the pen with the installation of the SIM card seat side of the small yellow point, eject the deck, remove the deck after the SIM card folder, and then into the original place, the corresponding antenna tight on the good, then DC power supply (12V / 2A) into the host, if built-in power supply (according to customer needs to install built-in battery), you can use the built-in power supply, and the power to open, the indicator light is always bright, then in the wireless detection state, about 20 seconds After the indicator light to orange slow flash, and then turn green light, according to the fourth method of the manual method into the phone number, then the indicator light to red light (the host is looking for GSM network and detect SIM card state) If the host detects and stores the phone number successfully, the indicator light turns on to green. Click the wireless remote control arming key, the indicator light to the green light slow flash, that the host into the normal state of the armed; if the wireless detector trigger, the host red light slow flash, that the host is in alarm state; if the host red light flash, Indicates that the host is in the incoming / SMS remote control state. If the host does not have a phone number, the indicator light turns on to a green light, indicating that the host is disarmed and re-enter the phone number as described above.
 
Fourth, how to set the host to call out the phone number (5 groups) and the host to send text messages (5)
1, the host is normally armed or disarmed state, the user can send a text message to the host to call out the phone number and send the message content to set, SMS format such as: password # opcode #.
Such as send a short message: 123456 # 51 # 13905950001 #, said the first phone number.
Such as send a short message: 123456 # 52 # 13905950002 #, said the second phone number.
Such as a short message: 123456 # 53 # 13905950003 #, said the first three phone numbers.
Such as a short message: 123456 # 54 # 13905950004 #, said the first four phone numbers.
Such as send a short message: 123456 # 55 # 13905950005 #, said the fifth phone number.
If you need to set the alarm center phone number user ID number, do:
Send a short message: 123456 # 71 # 88886666 # 0001 #, said the alarm center phone number is 88886666, user ID number is 0001. Alarm center phone (0-15); user ID number (4) alarm when the phone will dial the user ID (dual audio), this method is to match the cell center host to display user information.
Delete the host has been stored phone number can send text messages: 123456 # 51 ##, said the deletion of the first phone number. And so on.
Query the host has stored the phone number can send a short message: 123456 # 50 ##. The query host has stored the alarm center phone number
Send a message: 123456 # 70 ##.
2, the host has solidified the contents of seven text messages, the first one of the text messages corresponding to the wireless detector 1, the first two text messages corresponding to the wireless detector 2, the first three text messages corresponding to the wireless detector 3, the first 4 SMS corresponding to wireless detection 4 channel, the first 5 SMS corresponding to the wireless detector 5, the first 6 SMS corresponding to the wireless detector (6-16) Road, the first 7 SMS corresponding to the cable alarm (1-3) road.
Wireless detector 1 alarm: wireless alarm (zone 1).
Wireless Detector 2 Alarm: Wireless alarm (zone 2).
Wireless Detector 3 Alarm: Wireless alarm (zone 3).
Wireless detector 4 alarm: wireless alarm (zone 4).
Wireless Detector 5 Alarm: Wireless alarm (zone 5).
Wireless Detector i Alarm: Wireless alarm (zone i). (Wireless i = 6-16)
Note: 6 Road from the 16th Road, the contents of the same SMS, followed by the corresponding wireless zone.
Port I1, I2, I3 Alarm: Wired alarm (zone j). (Wired j = 1-3)
Note: the first road from the first three to the same, the contents of the same SMS, followed by the corresponding wired zone.
The user can send a text message to replace the SMS content:
Such as send a short message: 123456 # 81 # front door was opened #, instead of wireless alarm (zone 1).
Such as a short message: 123456 # 82 # in the door was opened #, instead of wireless alarm (zone 2).
Such as a short message: 123456 # 83 # back door was opened #, instead of wireless alarm (zone 3).
Such as send a short message: 123456 # 84 # left door was opened #, instead of wireless alarm (zone 4).
Such as a short message: 123456 # 85 # right door was opened #, instead of wireless alarm (zone 5).
Such as send a short message: 123456 # 86 # living room was in the #, instead of wireless alarm (zone i). (Wireless i = 6-16)
Such as send a short message: 123456 # 87 # kitchen someone into the #, instead of cable alarm (zone j). (Wired j = 1-3)
Inquiry SMS content: 123456 # 80 ##
Note: User self-made SMS content of not more than 6 Chinese characters or 24 English letters.
 
Fifth, how to test the host's alarm function
    After the host is disarmed, the user can use the remote control (armed key) or send text messages (123456 # 1 # 1 #)
To arm. If the main unit is armed, the green light flashes. If the cable input triggers the alarm (IN1, IN2, IN3 is short to the ground or ground disconnected) or the wireless detector triggers the alarm (wireless infrared, wireless door, remote control Emergency button and other actions), or remote into the system to trigger the alarm (enter the password 123456 #, then press 3 # 1 #), will make the host alarm message.
1, if the host to open the SMS alarm function, according to the trigger port (wired IN1, wired IN2, wired IN3, wireless detectors) to send the corresponding text messages, send text messages and then call the alarm. If the host turns off the SMS alarm function, call the phone directly.
2, the alarm, the user can listen to the scene after the phone can also be remote control, no need to enter the password, you can directly press 3 # # # so that the host immediately issued a live alarm, press 3 # 0 # off the scene alarm sound.
3, the alarm, the user can listen to the phone can also be remote control, no need to enter the password, press 4 # 1 # to open the monitor, press 4 # 0 # close monitor.
4, the alarm, the user connected to the phone, the scene can speak, no need to enter the password, you can directly press the 93 # 1 # so that the host immediately issued a master's voice, press 93 # 0 # off the scene speech.
5, the alarm, the user connected to the phone, if not Pirates of the situation, the user can directly press the # 1 # # so that the host to re-arm, the host will not be down to call other phone.
6, the alarm, the scene personnel can press the remote control disarm key, exit the alarm state.
7, the normal use, if the built-in battery, when the external power supply or re-come, the host will send text messages to inform the user.
8, the owner can remote control by phone, but first enter the password before further operation.
 
6, how to send short messages or call to set the host function
Users send text messages to the host, SMS format such as: password # opcode #. After the host will receive a reply:
Disarmed; SMS alarm: open; telephone alarm: open; alarm sound: open; arm and disarm alarm center: off; deployment center: off; disarm center: off
The user into the host phone, enter the password 123456 #, after a drop into the remote alarm host function settings (30 seconds
Do not enter the correct password automatically hang up), such as open alarm, you can press: 3 # 1 #, and then hang up.
Operation instructions:
(1) Bail disarmed: 1 # 1 # (out of all arming), 1 # 2 # (at home local deployment) 1 # 0 # (disarm)
(2) immediately open the scene alarm: 3 # 1 # (open), 3 # 0 # (off)
(3) immediately open monitor: 4 # 1 # (open), 4 # 0 # (off), the system default: open
(4) alarm sound switch: 11 # 1 # (open), 11 # 0 # (off), the system default: open
(5) SMS switch: 12 # 1 # (open), 12 # 0 # (off), the system default: open
(6) telephone switch: 15 # 1 # (open), 15 # 0 # (off), the system default: open
(7) arm and disarm alarm center telephone switch: 17 # 1 # (open), 17 # 0 # (off), the system default: off
(8) Arming center telephone switch: 18 # 1 # (open), 18 # 0 # (off), the system default: off
(9) disarm center telephone switch: 19 # 1 # (open), 19 # 0 # (off), the system default: off
(10) check zone arm and disarm state: 30 ##
(11) Change password: 31 # Password (0-6 digits) #
(12) zone alone arming: 38 # (1-16 wireless zone / 21-23 cable zone) # (armed)
(13) zone separate disarm: 39 # (1-16 wireless zone / 21-23 cable zone) # (disarm)
(14) Inquiry phone number: 50 ##
(15) Save the user first group number: 51 # phone number (0-15 bit) #
(16) save the user second group number: 52 # phone number (0-15 bit) #
(17) Save the user The third group number: 53 # Phone number (0-15 bit) #
(18) save the user fourth group number: 54 # phone number (0-15 bit) #
(19) save the user fifth group number: 55 # phone number (0-15 bit) #
(20) Inquiry Center: 70 ##
(21) Alarm center number: 71 # Telephone number (0-15 digits) # 4 digits Local number #
(22) Storage center number: 78 # Phone number (0-15) #
(23) Disarming Center Number: 79 # Phone Number (0-15) #
(24) Inquiry SMS content: 80 ##
(25) stored wireless zone 1 alarm SMS: 81 # SMS content (0-6 words) #
(26) stored wireless zone 2 alarm SMS: 82 # SMS content (0-6 words) #
(27) stored wireless zone 3 alarm SMS: 83 # SMS content (0-6 words) #
(28) stored wireless zone 4 alarm SMS: 84 # SMS content (0-6 words) #
(29) stored wireless zone 5 alarm SMS: 85 # SMS content (0-6 words) #
(30) stored wireless zone i alarm SMS: 86 # SMS content (0-6 words) #, (wireless i = 6-16)
(31) stored line alarm SMS: 87 # SMS content (0-6 words) #
(32) Query Port Status: 90 ##
(33) Set output port 1: 91 # 1 # (high), 91 # 0 # (low)
(34) Set the output port 2: 9